2Department of Medical Physics, Dokuz Eylül University Institute of Health Sciences, İzmir-Turkey
3Department of Radiology, Dokuz Eylül University Faculty of Medicine, İzmir-Turkey DOI : 10.5505/tjo.2019.2009 OBJECTIVE
This study aimed to compare the dose-volume parameters of organs at risk (OAR) (bladder, rectum, sigmoid and bowel) for the bladder filling of 50cc versus 150cc in high-dose-rate (HDR) (3-D) vaginal cuff (VC) brachytherapy (BRT).
METHODS
The treatment data of eight hysterectomized patients with gynecological malignancy who received postoperative
pelvic external radiotherapy (RT)+3-D HDR VC-BRT were analyzed. Recontouring was performed
on CT images, and BRT plans were reformed. Proximal 1/3 vagina was treated in all patients
using a cylinder. A total dose of 18 Gy (3x6Gy) was given (0.5 cm depth from the vaginal mucosa). OAR
and clinical target volume (CTV) were recontoured in a 3-D manner. Afterwards, treatment planning
was performed by a medical physicist using the BRT treatment planning system. Bladder V50%, D50%
and D2cc, rectum D2cc, sigmoid D2cc, bowel D50% and D2cc were recorded from the dose-volume
histograms obtained in the treatment planning system. Paired comparisons were made for the parameters
above for the bladder filling of 50cc versus 150cc. Two different amounts of bladder filling were
compared using the Wilcoxon Signed-Rank Test in the SPSS 15.0 statistics program.
RESULTS
Bladder D50% decreased (p=0.012) while bladder D2cc increased (p=0.025) in the case of 150cc bladder
filling instead of 50cc. Rectum D2cc showed a statistical trend for increase (p=0.05); however, bowel
D50% decreased (p=0.012) in 150cc bladder filling compared to 50cc.
CONCLUSION
The statistically significant decrease in bladder and especially bowel D50% parameters supports filling