2Deparment of Radiation Oncology, İstanbul University Faculty of Medicine, İstanbul-Türkiye DOI : 10.5505/tjo.2022.3819
Summary
OBJECTIVEThe aim of the study is to investigate the best radiotherapy modality in breast cancer patients regarding obtaining more conformal dose distribution while sparing the surrounding healthy tissues around the tumor using hybrid planning techniques.
METHODS
The study was conducted retrospectively using computed tomography images of 20 breast cancer patients,
10 right and 10 left received radiotherapy. After preparing three-dimensional conformal radiotherapy
(3DCRT), intensity modulated radiotherapy (IMRT), and volumetric modulated arc therapy
(VMAT) plans, IMRT based hybrid plans, named as 3DCRT+IMRT, IMRT+VMAT, and created with
50-50% dose weighted combinations for each patient using 3DCRT and VMAT. Dose volume histogram
data were used to evaluate the plan quality. The comparison parameters are critical organ (OAR) doses,
homogeneity index (HI), conformity index (CI), and monitor unit (MU) number.
RESULTS
Among the hybrid plans created with IMRT, the CI and HI values for the right and left breast irradiation
were found to be the best in IMRT+VMAT hybrid plans and the doses to critical organs could be
reduced using the 3DCRT+IMRT hybrid plans. At the same time, the quality of the plan increased by
reducing the contralateral breast dose, irradiated breast volume, and heart dose. IMRT+3DCRT hybrid
application should be considered as an option to reduce critical organ doses.
CONCLUSION
In cases that critical organ doses need to be reduced, IMRT+3DCRT hybrid technique should be considered
as an alternative option.
Introduction
Cancer is a group of diseases that consists of uncontrolled proliferation of cells and differs in cell behavior, clinical appearance, and treatment approach. It is important to determine the appropriate treatment to control the disease locally. When the cancer map of Turkey is examined, approximately 150,000 new cancer cases are diagnosed every year. Breast cancer is most common in women.[1] Breast cancer, which is the most common type of cancer in women in the United States (USA) and England, also has the highest mortality rate among cancer types in women.[2] Breast cancer is a hormone dependent disease. The proliferative effect of estrogens in the mammary epithelium may lead to mutations by increasing the possibility of DNA misreplication. Many known risk factors are associated with the duration and level of endogenous or estrogen stimulation. Early menarche, regular ovulation, and late menopause in premenopausal women, obesity, and hormone treatments in postmenopausal women are factors that increase estrogen exposure.[3] In addition, the incidence of breast cancer increases with age, especially after the age of 45-50.[4] Surgery, radiotherapy, chemotherapy, and hormone therapy are used in the treatment of breast cancer. Among these treatment modalities, radiotherapy has an important role as primary and adjuvant treatment.[5] Studies on breast cancer treatment have shown that radiotherapy reduces the 10-year risk of any local or distant recurrence from 35% to 19%, and the 15-year risk of breast cancer death from 25% to 21%.[6]The aim of radiotherapy is to accurately deliver high radiation dose to the target volume without exceeding the tolerance doses of critical organs.[7] Different radiotherapy techniques are needed because of the anatomical structure of the breast and heart, the contralateral breast received radiotherapy before, the cardiac diseases, the anatomical structure of the heart, the proximity of the heart to the chest wall, and the previous pulmonary disorders.[8] It is difficult to give the desired dose to the tumor without exceeding the reference doses of the critical organs around the target volume with the three dimensional conformal radiotherapy (3DCRT) technique.
In recent years, techniques such as IMRT and VMAT have been widely used, and there has been a perception that conformal techniques are no longer needed. This study shows that critical organ doses can be reduced by using advanced techniques such as IMRT and conformal techniques together.
The dose applied to the tumor can be increased while the doses received by the surrounding tissues can be minimized with innovative planning techniques such as volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT).[9] Thus, a good local control ratio can be achieved.
Each radiotherapy technique has both advantages and disadvantages. With 3DCRT, some of the volume of critical organs adjacent to the tumor is exposed to high doses. In other treatments with IMRT and VMAT, healthy tissues are exposed to a low dose bath. In order to eliminate the disadvantages of the techniques, hybrid treatment methods have been developed by using a combination of different techniques. The hybrid technique created by the combination of 3DCRT and IMRT techniques was first used in the treatment of breast cancer.
The purpose of current study is to investigate the plan quality of IMRT, and hybrid techniques based on IMRT in breast cancer patients by comparing the doses to critical organs and the conformity and homogeneity indexes.
Methods
Twenty women breast cancer patients, ten of whom were left-sided and ten of whom were right-sided, received radiotherapy the Istanbul University Oncology Institute, were randomly selected for this study. The breast volumes were ranging between 500 and 1500 cm3 for left-sided and 600-1700 cm3 for right-sided patients
Image Data Acquisition
The computed tomography (CT) images of the patients
were obtained using Philips Brillance Big Bore computed
tomography device. While obtaining CT images,
immobilization tools were used to accurately repeat
the treatment position and to ensure the stability of the
patient. The patients were placed on an inclined plane
with the head gantry and supine, and the arm was fixed
on the head on the side of the breast to be irradiated
with the vacuum bed. CT images were acquired using
the varian real-time position management system
(RPM). While acquiring the breath-controlled CT of
the patient, the amplitude (amplitude) and breath hold
(breath holding) options of the RPM system were selected.
With this technique, it is aimed to reduce the
doses received by the ipsilateral lung and heart. The CT
dataset were transferred to the Eclipse (Varian Medical
Systems) 15.6 treatment planning system (TPS).
Delineation of Target Volume and OARs
The clinical target volume (CTV), ipsilateral lung, contralateral
lung, heart, and contralateral breast tissues
were contoured by the radiation oncologist in accordance
with the recommendations of the ICRU protocols
50, 62, 83. No margin was given to the contoured
CTV, and treatment plans were prepared directly to the
breast tissue.
Treatment Planning and Dose Prescription
Five different treatment plans were prepared on CT
data of patients by same medical physicist in Eclipse
15.6 TPS. First, the plans were created using 3DCRT,
IMRT, and VMAT planning techniques for each patient.
Then, IMRT+3DCRT and IMRT+VMAT hybrid
plans were generated for each patient by combining
the 3DCRT, IMRT, and VMAT plans. Thus, each hybrid
plan was consisting of two components. The dose
prescription of each component of hybrid plan was
made to be 50% of the fraction dose. The isocenters of
CTVs in all plans were the same point. In the prepared
treatment plans, HD-MLC was used and calculations
were performed using the Analytical Anisotropic Algorithm
with a dose grid of 0.25 cm. The prescription
dose to CTV was 5000 cGy in 25 fractions for all plans.
All plans were created with 6 MV photon beams from
a Varian Trilogy linac equipped. The dose rate was selected
as 600 MU/min. The dose normalization was
made so that 95% of the CTV receiving 4500 cGy.
• Three-dimensional conformal radiotherapy
(3DCRT) plan
3DCRT plans were prepared using the two tangential
fields with beam angles ranging from 300°-100° for the
left breast and 50°-200° for the right breast. The table
angle was 0° and collimator angles were adjusted to be
15°-345° or 30°-330° according to the patient anatomy.
• Intensity modulated radiotherapy (IMRT) plan
IMRT plans were created with a total of seven angles
obtaining by choosing 2 non-reciprocal tangential
angles for all patients and adding 15 degrees to these
angles. The defined beam angles for the left-sided and
right-sided breast cancer patients were 300°, 315°, 330°
-100°, 85°, 70°, 55°, and 50°, 35°, 20°-200°, 215°, 230°,
245°, respectively. The selection of the beam angles
may vary depending on the patient anatomy.
Table angle is 0° and collimator angles are adjusted to be 15°-345° or 30°-330° according to the patient anatomy.
• Volumetric modulated arc therapy (VMAT) plan
Two partial arc was used in VMAT plans for all patients.
In the left-sided breast cancer treatment plans,,
the two arcs were set from 300° to 160° (clockwise) and
160° to 300° (counterclockwise), respectively. In rightsided
breast cancer treatment plans, the two arcs was
set from 200° to 50° (clockwise) and 50°-200° (counterclockwise),
respectively. Table angle is 0° and collimator
angles are adjusted to be 15°-345° or 30°-330°
according to patient anatomy.
• Hybrid plan
IMRT+3DCRT and IMRT+VMAT hybrid plans, which
are separate combinations of IMRT and VMAT plans,
were prepared with equal dose weights (50%-50%).
The prepared IMRT and their hybrids, 3DCRT+IMRT,
were normalized so that 95% of the target volume received
4500 cGy in the IMRT+VMAT plans.
The critical organ dose limits are given in Table 1.[10,11]
Table 1 Critical organ dose limits for OARs
The 4500 cGy dose distributions and beam angles for IMRT, IMRT+3DCRT, and IMRT+VMAT are shown in Figures 1-3, respectively.
Figure 1 shows IMRT, Figure 2 shows 3 DCRT+IMRT hybrid plans, and Figure 3 shows IMRT+VMAT hybrid plans.
Fig. 1. The dose distributions of intensity modulated radiotherapy plan.
Comparison of Treatment Plans
The comparisons of treatment plans were performed
based on dose volume histogram (DVH) data. The
comparisons were made considering the PTV, OAR
doses of each patient, and CI, HI, MU data. The statistical
analyses were conducted using the IBM SPSS (version
26.0) software package homogeneity index (HI)
and conformity index (CI) values were calculated in
five plans for comparisons to be made in terms of plan
quality. The HI values were calculated by considering
the equation recommended in the ICRU 83 report.
In the equation [12] the doses represent the following explanation;
D2%=Dose received by 2% of target volume (minimum dose received by target)
D98%=Dose received by 98% of target volume (maximum dose received by target)
D50%=Defined as the dose received by 50% of the target volume.
The HI value approaching "0" indicates that a more homogeneous treatment plan is obtained.
In this study, the formulation defined by RTOG was used for the CI value. CI formula;[13]
VRI=Reference isodose volume
TV=Defined as the target volume.
According to this formulation, the ideal value for a conformal plan is "1". A CI value between "1" and "2" indicates that the treatment is suitable for RT. As the conformity index value gets to "1" closer, the quality of the plan increases, and as it gets farther away, it decreases.
The comparison of the data obtained in the prepared treatment plans was made with the Wilcoxon Signed Ranks test belonging to the SPSS statistical program. As a result of the comparisons, the statistical p<0.05 condition obtained from the SPSS program was accepted as a significant difference. The obtained mean, standard deviation, and p values were used in the plan quality assessment.
Results
The calculated CI and HI values for IMRT, IMRT+3DCRT, and IMRT+VMAT plans are shown in Tables 2 and 3, respectively.The ipsilateral lung V20, V10, V5, mean dose, contralateral lung V10, V5, mean dose, heart V30, V5, mean dose, contralateral breast V5, mean dose, max dose, and 5 Gy dose volume values are shown in Table 4 for the right breast irradiations and in Table 5 for the left breast irradiations.
Table 2 CI values for IMRT and IMRT based hybrid plans in the right and the left breast patients
Table 3 HI values for IMRT and IMRT based hybrid plans in the right and the left breast patients
Table 4 Critical organ doses in the right breast patients
Table 5 Critical organ doses in the left breast patients
The MU values of IMRT, IMRT+3D, and IMRT+VMAT hybrid plans for the right and left breast irradiations are shown in Table 6.
Discussion
The present study was prepared using computed tomography images of 20 breast cancer patients (10 left-sided and 10 right-sided). First, IMRT, 3DCRT, and VMAT plans were generated for all patients. Then, IMRT based hybrid plans, as named 3DCRT+IMRT and IMRT+VMAT were composed. The comparisons of treatment plans in terms of target coverage and homogeneity and normal tissues doses were performed using DVH data.There were no statistically significant differences among IMRT, IMRT+3DCRT, and IMRT+VMAT plans in CI and HI for all patients. The CI values calculated for the IMRT+VMAT hybrid plans created with the VMAT plan contribution were closer to the ideal value than that of the 3DCRT+IMRT hybrid plans created with the 3DCRT contribution.
The 3DCRT+IMRT and IMRT+VMAT hybrid plans did not contribute to the improvement of the HI value. The ipsilateral lung V10, V5, mean dose, contralateral lung V10, V5, mean dose, heart mean dose, contralateral breast V5, mean and max dose, and the body volume receiving a dose of 5 Gy were lowest in 3DCRT+IMRT hybrid plans for the right and left breast irradiations.
When similar studies in the literature are evaluated; In the study conducted by Mayo et al.[14] with 5 patients from each right breast and left breast, the convergence prepared tangent plan (3DCRT), IMRT plan, hybrid plans of these plans were compared. Compared to the IMRT plan alone, they reported lower doses given to healthy tissues such as lungs and heart in hybrid plans. Ramasubramanian et al.[15] conducted a study with 26 left breast patients and evaluated hybrid VMAT (H-VMAT) plans, which are a combination of 3DCRT and VMAT plans. They stressed the importance of hybrid plans for PTV coverage, CI, HI improvement, and reduction of critical organ doses.
Doi et al.[16] reported that the HI and CI values of H/VMAT plans, which are hybrids of 3DCRT and VMAT plans, were better than 3DCRT for 35 left breast and 35 right breast patients. They also stated that ipsilateral lung, contralateral lung mean and V5 (%) and mean heart dose values were lower in H-VMAT technique than VMAT. The studies have been emphasized that the hybrid technique reduces the doses of critical organs compared to VMAT plans.
Farace et al.[17] prepared 3DCRT and IMRT plans for a total of 78 breast cancer patients, 36 right and 42 left. They observed that the mean dose values of the H/3D-IMRT plans, lung V5 (%), contralateral breast V5 (%), heart V5 (%), heart V2.5 (%), and especially the heart were lower than the IMRT plan alone. They also stressed that the HI and CI values of the H-IMRT plans were better.
In our study, it has seen that the best CI and HI value were obtained in the plans created using IMRT+VMAT hybrid plans for the right and left breast irradiations. While, the ipsilateral lung volume receiving 20 Gy (V20) were found lowest in IMRT plans for the right breast and in IMRT+VMAT hybrid plans for the left breast. The contralateral and ipsilateral lung volume receiving 10 Gy and 5 Gy were lowest in IMRT+3DCRT for both left-sided and right-sided breast.
The contralateral breast doses had the in the IMRT+3DCRT for all patients. The lowest heart volume receiving 30 Gy was obtained with IMRT+VMAT technique in left breast irradiations. In right and left breast irradiations, the lowest heart Dmean doses and V5 (%) were acquired with IMRT+3DCRT hybrid plans. The lowest values of MU values were obtained in IMRT+3DCRT plans, while the highest values were obtained in IMRT plans. When our study is evaluated together with similar studies in the literature, it shows parallelism.
According to the findings of this study, the IMRT and 3DCRT hybrid plans in left and right breast irradiations were calculated as heart V5 (%), heart Dmean, contralateral breast V5 (%), contralateral breast Dmean, contralateral breast Dmax, ipsilateral and contralateral lung V5 (%), and V10 (%) appears to decrease lung Dmean doses. Hybrid techniques should be considered as an important option in reducing critical organ doses without deteriorating the plan quality in the right and left breast irradiation.
The our study had been concluded that the CI and HI values for right and left breast irradiation were found to be the best in IMRT+VMAT hybrid plans and the doses to critical organs could be reduced with the 3DCRT+IMRT hybrid plans.
IMRT+3DCRT hybrid application should be considered as an option in reducing radiation doses to critical organ for both left- and right-sided breast cancer patients.
Peer-review: Externally peer-reviewed.
Conflict of Interest: All authors declared no conflict of interest.
Ethics Committee Approval: The study was approved by the İstanbul University Institute of Health Sciences Ethics Committee (no: 141353, date: 19/03/2021).
Financial Support: None declared.
Authorship contributions: Concept - S.Ç., H.B.B., C.K.A.; Design - S.Ç., H.B.B.; Supervision - S.Ç., H.B.B., C.K.A.; Funding - S.Ç., H.B.B., C.K.A.; Materials - S.Ç., K.İ.; Data collection and/or processing - S.Ç., H.B.B., K.İ.; Data analysis and/or interpretation - S.Ç., H.B.B.; Literature search - S.Ç., H.B.B.; Writing - S.Ç., H.B.B.; Critical review - S.Ç., H.B.B.
References
1) T.C. Sağlık Bakanlığı Türkiye Halk Sağlığı Kurumu.
Türkiye istatistikleri, 2019. Available at: https://sbsgm.
saglik.gov.tr/Eklenti/40564/0/saglik-istatistikleri-yilligi-
2019pdf.pdf. Accessed Jan 12, 2023.
2) American Cancer Society. Breast cancer facts & figures
2019-2020. Available at: https://www.cancer.org/content/
dam/cancer-org/research/cancer-facts-and-statistics/
breast-cancer-facts-and-figures/breast-cancer-facts-
and-figures-2019-2020.pdf. Accessed Jan 12, 2023.
3) Mincey BA. Genetics and the management of women at
high risk for breast cancer. Oncologist. 2003;8(5):466-73
4) Topuz E, Aydıner A, Dinçer M. Meme kanseri. İstanbul:
Nobel Tıp Kitabevi; 2003.
5) Fisher B, Anderson S, Bryant J, Margolese RG,
Deutsch M, Fisher ER, et al. Twenty-year follow-up
of a randomized trial comparing total mastectomy,
lumpectomy, and lumpectomy plus irradiation for
the treatment of invasive breast cancer. N Engl J Med
2002;347(16):1233-241.
6) Early Breast Cancer Trialists" Collaborative Group
(EBCTCG); Darby S, McGale P, Correa C, Taylor C,
Arriagada R, et al. Effect of radiotherapy after breastconserving
surgery on 10-year recurrence and 15-year
breast cancer death: meta-analysis of individual patient
data for 10,801 women in 17 randomised trials.
Lancet 2011;378(9804):1707-16.
7) Şahinler İ, Ergen ŞE. Radyasyon onkolojisinde temel
yaklaşımlar. İ.Ü. Cerrahpaşa Tıp Fakültesi, Sürekli Tıp
Eğitimi Etkinlikleri Sempozyum Dizisi No: 79. İstanbul;
2012.
8) Askeroglu MO. Meme ışınlamasında düzleştirici filtreli
ve filtresiz ışınların karşılaştırılması. Yüksek
Lisans Tezi. İstanbul: Acıbadem Mehmet Ali Aydınlar
Üniversitesi; 2018.
9) Intensity Modulated Radiation Therapy Collaborative
Working Group. Intensity-modulated radiotherapy:
current status and issues of interest. Int J Radiat Oncol
Biol Phys 2001;51(4):880-914
10) Radiation Therapy Oncology Group. RTOG 1005.
A phase III trial of accelerated whole breast irradiation
with hypofraction plus concurrent boost versus
standard whole breast irradiation sequential boost for
early-stage breast cancer; 2011. Available at: http://
rpc.mdanderson.org/rpc/credentialing/files/RTOG-
1005%5B1%5D.pdf. Accessed Jan 12, 2023.
11) Rudra S, Al-Hallaq HA, Feng C, Chmura SJ, Hasan Y.
Effect of RTOG breast/chest wall guidelines on dosevolume
histogram parameters. J Appl Clin Med Phys.
2014;15(2):4547.
12) International Comission on Radiation Units and Measurements.
ICRU Report No: 83. Prescribing, Recording,
and Reporting Photon. Journal of the ICRU 2010;10(1).
13) Feuvret L, Noël G, Mazeron JJ, Bey P. Conformity
index: a review. Int J Radiat Oncol Biol Phys
2006;64(2):333-42.
14) Mayo CS, Urie MM, Fitzgerald TJ. Hybrid IMRT plans-
-concurrently treating conventional and IMRT beams
for improved breast irradiation and reduced planning
time. Int J Radiat Oncol Biol Phys 2005;61(3):922-32.
15) Ramasubramanian V, Balaji K, Balaji Subramanian
S, Sathiya K, Thirunavukarasu M, Radha CA. Hybrid
volumetric modulated arc therapy for whole breast
irradiation: a dosimetric comparison of different arc
designs. Radiol Med 2019;124(6):546-54.